Handle-height adjustment effects on gait kinetics in older adults while walking with a rollator

dc.contributor.advisorKwon, Young-Hoo
dc.creatorAvalos, Marco Antonio
dc.creator.orcid0000-0001-5724-0919
dc.date.accessioned2020-07-31T19:39:34Z
dc.date.created2020-05
dc.date.issued4/23/2020
dc.date.submitted20-May
dc.date.updated2020-07-31T19:39:34Z
dc.description.abstractAn increasing geriatric population has increased the demand for walking-aids among this population. The use of walking-aids requires proper adjustment to maintain adequate shared weight-bearing while maintaining correct posture. Current guidelines leave users with vague instructions not allowing for proper adjustment of these devices. The purpose of this investigation was to determine the effects of handle-height adjustment on gait kinematics and kinetics in able-bodied older adults when walking with an all-terrain rollator. Participants were tested while walking at 80 and 100% of their normal cadence. Thirty-three participants were recruited from the Denton, TX, area. Every participant signed an IRB approved Informed Consent Form. Participants were asked to complete 5 successful trials for each of the different handle adjustments (i.e., 48% of the user’s height, 55% of the user’s height, and wrist crease height) on two cadences (i.e., normal cadence and slow cadence); the participant was also asked to walk without the rollator as a control condition for each walking cadence condition. Participants were instructed to walk as naturally as possible while applying force over the rollator. Kinetic variables measured include ground reaction force, lower body resultant joint moment, postural back angles and walking velocity were extracted in order to see the effects of the rollator. Significant decrease in vertical, forward, backward, and inward GRF from 11.9-26.5% was seen, and, hip flexor, hip abductor from, and ankle plantar flexor and invertor moments up to 16% reduction, while an increased L4/L5 flexor moment by 25% were found while using the rollator. These effects were accompanied by a reduction of kyphosis from 1.3 to 1.4% and lordosis up to 1%, but with an increase in thorax flexion by 8-11% and shoulder elevation by 7-10%. The use of a rollator reduced the forces received by the lower limb joints, but a more stooped posture was acquired, increasing the stress over the L4/L5 joint. Rollator adjustment depends on the clinical goals set for the use of the device as well as the user’s need for mobility.
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://hdl.handle.net/11274/12331
dc.language.isoen
dc.subjectWalking
dc.subjectWalking-aids
dc.subjectRollator
dc.subjectHandle-height
dc.subjectPosture
dc.subjectKinetics
dc.titleHandle-height adjustment effects on gait kinetics in older adults while walking with a rollator
dc.typeThesis
dc.type.materialtext
local.embargo.lift5/1/2022
local.embargo.terms5/1/2022
thesis.degree.departmentKinesiology
thesis.degree.disciplineKinesiology
thesis.degree.grantorTexas Woman's University
thesis.degree.levelDoctoral
thesis.degree.nameDoctor of Philosophy

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AVALOS-DISSERTATION-2020.pdf
Size:
1.16 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.85 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
PROQUEST_LICENSE.txt
Size:
5.84 KB
Format:
Plain Text
Description: